A. Maximum operating temperature for most Solberg inlet air filter products is

220°F / 105°C. Temperatures in excess of this could cause damage to
elements, media and elastomers. High temperature products are
available.


B. Direction of flow is typically from the outside of the element to the inside of

the element. Most products have arrows indicating direction of flow on the
inlet and outlet ports.


C. Ensure that pipe/flange connections are adequately sealed so the

potential for leaks is reduced to a minimum.

2. Disconnecting side panel from housing.

A. Remove wing nut and washer holding each belly band to housing, Figure

C.2.1.

B. Remove bolt, washer, and nut on both belly bands, Figure C.2.2.



C. Carefully remove belly bands off of securing bolt and lift off of housing,

Figure C.2.3.

D. Carefully remove side panel off of securing bolts, Figure C.2.4.

Figure C.2.1: Wing nut, washer, and
securing bolt.

Figure C.2.2: Bolt, nut, and washer on belly band.