SOLBERG

Section C

PROCEDURES

*WARNING*

Before installing any Solberg STS unit, it is
essential that all packaging materials be
removed properly, prior to start up, to avoid
risk of contamination.


1. Installation.

A. All STS units are designed in a

“Straight Thru” pipe configuration.


B. Direction of flow is typically from the outside of inner tube assembly to the

inside of tube assembly to outlet of casting.


C. Ensure that pipe/flange connections are adequately sealed so no leaks

are present.


D. Mounting orientation is casting on top and bucket below so liquid can drain

to bottom of bucket for removal.


2. Removing Bucket.

*WARNING*

System must be off and canister must be
relieved of vacuum before opening. Proper
personal protection equipment must be worn
when servicing canister. Failure to comply
with these instructions could result in
implosion or personal injury.

A. Turn off vacuum pump/system.

B. Loosen T-Bolt clamps or release the torsion clips.

C. Remove clear bucket from casting.

Advertising