Backpage Parameters | 21

20 | Use with Hot Hand

BACKPAGE PARAMETERS

The

MWD

Pro has some additional controls that can only be editing

in a special mode called Backpage mode. Backpage mode is enabled
by pressing the

HH ENABLE

and

CALIBRATE

buttons simultaneously, as

indicated on the main control panel. Backpage mode can be exited by
pressing the two buttons simultaneously again.

In Backpage mode, the

EQ

controls and the Effect knob take on different

functions and the displays will change to indicate the parameter values.
For the

EQ

display, there are two letter abbreviations above some of the

columns that indicate the parameter controlled in Backpage mode. Select
the parameter to be edited with the left and right band select buttons
and adjust the value with the knob.

HH Enable
The

HH ENABLE

button will allow Hot Hand

®

control for an individual

preset so it can be used on one preset and not on another.

Calibration
The

MWD

Pro has a calibration feature which is only used in Hot Hand

mode. However, calibration is not required before use. The calibration
feature allows you to set the

MAXIMUM

point of the

DRIVE

sweep for any

position of your hand. Depending on your playing style, you may find it
useful to try some different calibration positions. The default and most
common use of calibration is to have your hand pointing straight up as
the maximum point of the

DRIVE

sweep. Calibration can also be useful

if you are putting the sensor on a headband or other alternate locations.
Calibration mode can only be enabled when

HH ENABLE

in

ON

. Calibra-

tion settings are saved per preset.

To perform a calibration:

1. Select a preset by pressing a footswitch.

2. Enable Hot Hand control by pressing the

HH ENABLE

button.

3. Press the

CALIBRATE

button to put the

MWD

Pro into Calibrate Mode.

4. Put the Hot Hand sensor into the desired calibration position.

5. Press the footswitch for the currently selected preset.

6. The Calibrate

LED

will blink to when the calibration is complete.

If you have trouble with calibration and need to get back to the default
setting, point the front of the sensor (the H logo) straight up towards the
ceiling and run the calibration procedure again.

125 250 500 1K 2K

(NG) (HG) (HS) (HA) (HR) (CR)

4K 8K

+12

-12

0

<

>

+12

-12

0

HH ENABLE

CALIBRATE

BACKPAGE

MODE

-