WIRING DIAGRAM NOTES

FUSE RECOMMENDATIONS

Location

A

: Should be rated for the lesser of the array, load and wire.

Location

B

: 5 - 10 amp fuse.

Location

C

: 1 amp fuse

=============================================================================

FIGURE 1 - Timer with ASC Controller

TIMER TERMINAL CONNECTIONS

Batt / Array (-):

To ASC BATT (-). (...or to Array (-) or Battery (-) )

Load (-):

To load (-).

Array (+): To ASC ARRAY (+): The wire from the SCT ARRAY (+) terminal does not carry any

current, therefore, small gauge wire may be used. (Wire as shown in diagram; this
connection MUST be made to the array side of the system's blocking diode.)

Batt / Load (+):

To ASC BATT (+) and additional wire connected to load (+)

LOAD May be a relay coil to increase load current capability of Timer. Negative side of load is

controlled. Do not connect Load (-) to system common.

=============================================================================

FIGURE 2 - Timer with ASC Controller with Low-Voltage Load Disconnect (LVD)

TIMER TERMINAL CONNECTIONS

Batt / Array (-):

To ASC BATT (-) (...or to Array (-) or Battery (-) )

Load (-):

To load (-)

Array (+): To ASC ARRAY (+): The wire from the SCT ARRAY (+) terminal does not carry any

current, therefore, small gauge wire may be used. (Wire as shown in diagram; this
connection MUST be made to the array side of the system's blocking diode.)

Batt / Load (+):

To ASC BATT (+)

LOAD May be a relay coil to increase load current capability of Timer. Negative side of load is

controlled. Do not connect Load (-) to system common.

=============================================================================

FIGURE 3 - Timer with Charge Controller with LVD (Non-ASC Controller)

TIMER TERMINAL CONNECTIONS

Batt / Array (-):

To Controller Batt (-) (...or to Array (-) or Battery (-) )

Load (-):

To load (-)

Array (+): If controller has blocking diode, this connection goes to Controller Array (+). If

controller does not have a blocking diode, install one as shown and wire this connection
to array side of blocking diode. The wire from the SCT ARRAY (+) terminal does not
carry any current, therefore, small gauge wire may be used. This connection MUST be
made to the array side of the system's blocking diode.

Batt / Load (+):

To Controller Batt (+)

LOAD May be a relay coil to increase load current capability of Timer. Negative side of load is

controlled. Do not connect Load (-) to system common.

=============================================================================

FIGURE 4 - Timer with Photo sensor

TIMER TERMINAL CONNECTIONS

Batt / Array (-):

To Controller Batt (-) (...or to Array (-) or Battery (-) )

Load (-): To load (-)

Array (+): To Photo sensor (either wire).

Batt / Load (+):

To Controller Batt (+) (or Battery (+) ), and a second wire to load (+) and a

third wire to the photo sensor

CONTROLLER No controller or blocking diode is needed for the operation of the timer and load.
LOAD May be a relay coil to increase load current capability of Timer. Negative side of load is

controlled. Do not connect Load (-) to system common.