CAUTION:

DO NOT START OR RUN THE ENGINE BEFORE ADDING OIL IN THE HYDRAULIC RESERVOIR AND OIL IN

THE

ENGINE.

OPERATING INSTRUCTIONS

WARNING: Read and thoroughly understand all instructions and safety information before operating

this log splitter. Failure to do so may cause serious injury or death. Do not allow anyone to operate

this log splitter who has not read this manual. As with all power equipment, a log splitter can be dan-

gerous if assembled or used improperly. Do not operate this log splitter if you have doubts or ques-

tions concerning safe operation. Call our customer service department at 1-800-525-8322 to address

these concerns.
Si no entiende ingles, se prefiere que busque alguien que interprete las instrucciones para usted.

STEP 1: The hydraulic reservoir must be filled with oil before operation. AW46 hydraulic oil is recommended when oil is needed. Automatic

transmisssion fluid can be substituted and should be used instead of hydraulic oil when temperatures are below 32 degrees F. Use only

clean oil and take care to prevent dirt from entering the hydraulic reservoir. Fill the hydraulic tank with approximately 3.5 to 4 gallons of

hydraulic oil.

CAUTION:

WHEN TIGHTENING THE BREATHER CAP ON THE TANK, POINT THE HOLE AWAY FROM THE ENGINE

AND THE OPERATOR ZONE.

ENGINE OIL RECOMMENDATIONS

For temperatures above 40 degrees F use an SAE 30W oil. Using multigrade oil may increase oil consumption. Using SAE 30W oil below 40

degrees F will resuilt in hard starting and possible engine bore damage. For temperatures below 40 degrees F use an SAE 10W-30 or SAE 5W-30

oil. Oil capacity is about 1.16 quart (1.1 liter).

STEP 2:

After the hydraulic reservoir and the engine crankcase are filled with oil, start the engine. The hydraulic pump should prime itself. With the

engine running, move the hydraulic valve lever toward the foot plate. This will cause the cylinder to extend and expel air. When the cylinder

is fully extended, retract it. Repeat this procedure several times. An erratic movement of the cylinder indicates that there is still air in the

system. Add about 1.0 to 1.5 gallons more. Five gallons will register just above the top fill line on the dip stick. The total capacity of the entire

hydraulic system is 6.5 gallons. NOTE: If the tank is overfilled it will tend to expel oil from the breather cap when the cylinder is retracted.

Cycle the cylinder again until it has a constant speed indicating that all air has been expelled.

Page 13

STARTING INSTRUCTIONS

Honda 240 Engine

Refer also to the Honda Engine Operating and Maintenance Instructions manual for your log splitter.

1) Move the fuel valve lever to the ON position.

2) To start a cold engine move the choke lever to the CLOSED position. To restart a warm engine leave the choke lever in the

OPEN position.

3) Move the throttle lever away from the MIN position, about 1/3 of the way toward the MAX position.

4) Turn the engine switch to the ON position.

5) Operate the starter (recoil starter). Pull the starter grip lightly until you bfeel resistance, then pull briskly. Return the starter grip gently.

Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter.

STOPPING THE ENGINE

To stop the engine in an emergency, simply turn the engine switch to the OFF position. Under normal consitions, use the

following procedure.

1) Move the throttle lever to the MIN position.

2) Turn the engine switch to the OFF position.

3) Turn the fuel valve lever to the OFF position.