Installation instructions, Ef28 electric fireplace – CFM Corporation EF28 User Manual

Page 5

Advertising
background image

5

EF28 Electric Fireplace

10010019

• Electrical Specifications

Voltage

120V ac, 60 Hz

Total Amps

8.4 Amps

Total Watts

1050W

Heater Rating

2 x 500W

Illumination

2 x 20W Low Energy Bulb

• Locating Your Fireplace

When choosing a location for your new fireplace, ensure the general instructions are
followed. Also, for best effect, install the fireplace out of direct sunlight.

• Clearance to Combustibles

Sides (Trim) .......................................... 0” (0 mm)

Sides (Outer casing) .......................... 3” (76 mm)

Floor .................................................... 0” (0 mm)

Front ............................................... 36” (914 mm)

Trim Top ............................................... 0” (0 mm)

• Cabinet Installation

Cabinets are available from your dealer, or may be supplied with your fireplace for
fast, convenient installation of your fireplace against an existing wall.
For instructions on handling and assembly of your cabinet, refer to separate installa-
tion instructions that come with the cabinet.

• EF28 Fireplace Dimensions

Installation Instructions

33�����” (850 mm)

26�����”

(685 mm)

5���”

(140 mm)

10019
EF28 dims
3/07

• Unit: EFJR4G1

Outer Casing

Trim

Trim Top

Advertising