chimney may be swept through the
appliance.

Horizontal lengths of flue must be
kept to a minimum and should not be
more than 150mm (6 inches) long.
The sealing face of the flue collar
should be coated with fire cement
before fixing to the body of the stove
using the two screws provided. The
blanking plate must be removed,
sealed with fire cement and refitted,
care being taken to ensure that the
fold on the blanking plate is in line
with the lugs on the firebox as shown
in Fig. 9. Ensure that the clamping
plate does not prevent the throat plate
from seating correctly. All flue
connections must be well sealed.
Ensure that the flat top or canopy is
securely bolted to the body of the
stove.

SOOT DOORS

It is possible to pass a 16 inch
diameter sweeps brush through the
appliance but in most back outlet
installations it will be necessary to
have a soot door to enable the
chimney to be swept. This may either
be in the actual brickwork of the

chimney or in the register plate.
Various types and positions of soot
doors are shown in figures 5 to 8.

PRE LIGHTING

CHECK

Before initial lighting the following
points should be checked :-

1. The bottom grate bars must all be
fitted and should move freely and
easily when the riddling mechanism
is operated.

2. The plates round the sides and
back of the grate must be in position
and sitting correctly.

3. The throat plate must be fitted in
the roof of the appliance and should
be checked to ensure that it has not
become dislodged in transit. The
method of location and positioning of
the throat plate is shown in fig 3.

4. The top or canopy must be securely
bolted to the body of the stove using
the fixings provided to ensure proper
sealing.

COMMISSIONING

On completion of the installation and
after allowing a suitable period of
time for the fire cement and mortar to
dry out, the stove should be lit and
checked to ensure that smoke and
fumes are taken from the appliance
up the chimney and emitted safely.
Also check all joints and seals. On
completion of the installation and
commissioning please leave the
operating instructions with the
customer and advise them on the use
of the appliance.

Register Plate

With Soot Door

Soot Door

Alternative

Positions

Rear Flue Connector

Fig. 8. Horizontal Register

Plate With Optional Vertical

Blanking Plate

Blanking Plate

Clamping Plate

with fold horizontal

Back of the Stove

Clamping plate finishes

flush with inside face of

firebox top and bottom.

with fire cement

Seal Blanking Plate

Fig. 9. Flue Blanking Plate.