Operation – Sure Heat FM35PHLP Patio Heater User Manual

Page 11

Advertising
background image

Operation

Do not attempt to "Light" the Heater if the odor of gas present!!

LIGHTING:

1. Remove the Access panel from the heater body exposing the gas regulator and the space for the
propane cylinder.

2. Rotate the valve toward you, so that the attaching threads are visible. Thread the propane cylinder
in place and ensure a tight seal.

3. Lower the propane cylinder into a vertical position and replace the panel.

4. Firmly press down on the control knob and turn left to the 9:00 o'clock position marked "ON".
Release the knob.

5. Hold the pilot control knob in and push the piezo button until the pilot fl ame appears.

6. Continue holding the pilot control knob for up to one (1) minute before releasing. Pilot should
remain lit.

7. Release Control Knob after 60 seconds. Pilot Light will remain lit. If not, return to Step 1.

8. If the pilot light does not come on, repeat Steps 4 and 5. NOTE: If a new tank has been put into
service, allow the gas to replace the air in the line. This can take up to 10 seconds.

9. To start the burner, rotate the Control Knob in a clockwise direction and stop at the desired
temperature position.

11

BEFORE TURNING GAS SUPPLY ON:

1. Your heater was designed and approved for outdoor use only. Do NOT use it inside a building,
garage, or any other enclosed area.

2. Make sure surrounding areas are free of combustible materials, gasoline,and other flammable
vapors or liquids.

3. Ensure that there is no obstruction to air ventilation.

4. Be sure all gas connections are tight and there are no leaks.

5. Be sure the cylinder cover is clear of debris.

6. Be sure any component removed during assembly or servicing is replaced and fastened prior to
starting.

BEFORE LIGHTING:

1. Heater should be thoroughly inspected before each use, and by a qualifi ed service person at least
annually.

2. If relighting a hot heater, always wait at least 5 minutes.

3. Inspect the hose assembly for evidence of excessive abrasion, cuts, or wear. Suspected areas
should be leak tested. If the hose leaks, it must be replaced prior to operation. Only use the
replacement hose assembly specifi ed by manufacturer.

Advertising