Safety instructions, Care of your opener, Maintenance schedule – Chamberlain Series 1200 User Manual

Page 27: Save these instructions, Warning

Advertising
background image

The remote control transmitter:

The opener must learn the code of any new remote
control. Page 29 explains how to program your
receiver and how to erase all codes if required. Self
service of your radio controls and remote controls is
not recommended. If service is needed, call the toll-
free number listed on the back page.

The remote control battery:

The green test light will glow and the opener will
operate when the remote control is activated.

If the test light is

dim or off, replace the battery.

The 12V battery should produce power for at least a
year.

Dispose of your old battery properly.

Once a Month

Manually operate door. If it is unbalanced or
binding, call for professional garage door service.

Check to be sure door opens & closes fully.
Adjust limits and/or force if necessary.
(See pages 24 and 25.)

Repeat the safety reverse test. Make any
necessary adjustments. (See page 26.)

Twice a Year

Check chain tension. Disconnect trolley first.
Adjust if necessary (See page 7.)

Once a Year

Oil door rollers, bearings and hinges.

The opener does not require additional
lubrication.

Do not grease the door tracks.

Weather conditions may cause some minor
changes in door operation requiring some re-
adjustments, particularly during the first year of
operation.

Pages 24 and 25 refer to the limit and force
adjustments. Only a screwdriver is required. Follow
the instructions carefully.

Repeat the safety reverse test (page 26) after any
adjustment of limits or force.

Care of Your Opener

27

IMPORTANT SAFETY INSTRUCTIONS

To reduce the risk of severe injury or death to persons:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Do not permit children either to operate or to play with the opener. Keep remote control in a

location inaccessible to children.

3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in

sight until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.

4. Check safety reversal system monthly. See page 26. The garage door

MUST reverse on contact

with a 2x4 board laid flat placed on the floor. If an adjustment is made to either the force or the limit
of travel, both adjustments may be needed and the safety reversal system must be checked.
Failure to properly adjust the opener may result in severe injury or death.

5. If possible, use the manual release only when the door is in a closed position. Caution should be

taken whenever the disconnect cord is actuated with the door open.

Weak or broken springs may

cause the door to fall rapidly, causing injury or death to persons.

6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3.

An improperly balanced door may not

reverse when required and could result in severe injury or death. Repairs to cables, spring
assemblies and other hardware must be made by a professional garage door person.

7. Disconnect the electric power from the garage door opener before making any repairs or removing

the covers.

8.

SAVE THESE INSTRUCTIONS.

Adjustment Label

(Located on the back panel)

KG

KG

1

3

9

7

5

1

3

9

7

5

Maintenance Schedule

Limit and force adjustment controls

WARNING

WARNING

Force Controls

Adjustment Label

(Located on the left side panel)

Limit Controls