Inspecting burners, Operating heater – Desa Tech S26NTA User Manual

Page 15

Advertising
background image

www.desatech.com

110361-01F

15

Figure 20 - Pilot

Thermocouple

Pilot Burner

Ignitor Electrode

OPERATING HEATER

Continued

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-

terns often.

PILOT FLAME PATTERN

Figure 21 shows a correct pilot flame pattern. Figure

22 shows an incorrect pilot flame pattern. The incor-

rect pilot flame is not touching the thermocouple.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise

to the OFF

position.
Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any

comfort level between HI and LO. The ther-

mostat will gradually modulate the heat output

and flame height from higher to lower settings

or pilot, in order to maintain the comfort level

you select. The ideal comfort setting will vary

by household depending upon the amount of

space to be heated, the output of the central

heating system, etc.
Note:

Selecting the HI setting with the control

knob will cause the burners to remain fully on,

without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions

, page 14.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 Lighting

Instructions

, page 14

This will cause the thermocouple to cool. When the

thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 22
• turn heater off (see To Turn Off Gas to Appliance)
• see Troubleshooting, page 18
Note:

The correct pilot flame on natural gas units

will have a slight curve, but flame should be blue

an have no yellow or orange color.

Figure 21 - Correct Pilot Flame Pattern

(Natural Gas Shown)

Figure 22 - Incorrect Pilot Flame Pattern

(Natural Gas Shown)

Thermocouple

Pilot Burner

Thermocouple

Pilot Burner

Figure 23 - Correct Flame Pattern with

Control Knob Set to High Flame

Figure 24 - Incorrect Flame Pattern with

Control Knob Set to High Flame

Approx.
3-6"
Above
Top of
Logs

More
Than 8"
Above
Top of
Logs

BURNER FLAME PATTERN

Figure 23 shows a correct burner flame pattern.

Figure 24 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect,
• turn heater off (see To Turn Off Gas to Appliance)
• see Troubleshooting, page 18

Advertising