Technical specification – SUUNTO VYTEC User Manual

Page 70

Advertising
background image

68

•

the blinking of the bar graph stops, when the PO

2

is below 0.5

bar

•

audible alarms are given and the actual PO

2

value blinks when

it exceeds the preset limit

•

in dive planning the maximum depth according to the O

2

% and

maximum PO

2

selected.

6.4. TECHNICAL SPECIFICATION

Dimensions and weight:
Vytec:

•

Diameter:

61mm [2.4in].

•

Thickness:

28mm [1.1in].

•

Weight:

68g [2.4 oz].

Transmitter:

•

Max. diameter: 40 mm [1.57 in].

•

Length:

80mm [3.15 in].

•

Weight:

118g [4.16 oz].

•

Rated working pressure: 300 bar [4000 psi], maximum

allowed pressure 360 bar [5000 psi].

•

Display resolution:1 bar [1 psi].

Depth Gauge:

•

Temperature compensated pressure sensor.

•

Salt water calibrated, in fresh water the readings are about

3% smaller (calibrated complying with prEN 13319).

•

Maximum depth of operation: 80 m [262 ft] (complying with

prEN 13319).

•

Accuracy: ± 1% of full scale or better from 0 to 80 m [262 ft] at

20°C [68°F] (complying with prEN 13319).

•

Depth display range: 0 … 150 m [492 ft].

•

Resolution: 0.1 m from 0 to 100 m [1 ft from 0 to 328 ft].

Temperature display:

•

Resolution:

1°C [1.5°F].

•

Display range:

-9 ... +50°C [-9 ... +122°F].

•

Accuracy:

± 2°C [± 3.6°F] within 20 minutes of

temperature change.

Calendar Clock:

•

Accuracy:

± 25 s/month (at 20°C [68°F]).

•

12/24 h display.