TC-Helicon Quintet MIDI System Exclusive

Version 1.1

Note: All numerical values will appear in HEXADECIMAL notation unless otherwise indicated:

0xF0 = F0h = F0 – The latter value is the expression of the hex numeral used.

Decimal equivalents will appear in brackets after their hex counterparts:

0xF0 = F0h = F0 = (240)
0x64 = 64h = 64 = (100)

General message format:


F0

MIDI System exclusive message start

00

3 byte manufactors ID for TC-Helicon

01

...

38

...

<Device ID>

System exclusive device ID (user parameter)

4D

Quintet model ID

<Message ID>

Quintet message type identifier (see table below)

<Data>

Data – depends on message type (see format description.
below)



F7

MIDI System exclusive message terminator

Preset numbers

Preset numbers are represented in the SysEx messages as 1 byte.
Preset number zero is the currently edited preset, and 1 to 50 are as is.

Message data format

The format of the data used/needed in the different SysEx messages depends on the type of
message. Below are descriptions for each message type explaining data formatting.

SysEx message type

Identifier

Quintet Request Preset

17

Quintet Request All Presets

16

Quintet Preset Data Package

18

All CCs Request

32