background image

Part Number

Flow Meter

Calibration Number Pulses/Liter

Input Number for 70 Console -
Calibration Number Pulses/Gallon

90-50230

TeeJet 801

83

314

57-00079

LH-10D

242

916

57-00080

LH-16D

79

299

57-00081

LH-20D

50

189

57-00082

LH-26D

24

91

57-00094

LH-40D

21

79

Pulses per liter x 3.785 = Pulses per gallon (input into 70 console)

Pulses per gallon / 3.785 = Pulses per liter (input into 70 console)

Function

Key

Description

1. Power On

PRO

The unit will power on and show the fi rst working screen.

US Units

2000>G

1500 g

Metric Units

7550 > L

5678 L

2. Power Off

↑ ↓

The unit will power off.

Function

Display

Possible Actions

Comments

Main Screen Target
Volume

2000>G

1500 g
7550 > L

5678 L

↑ ↓

to modify Target volume

Note: The numeric value on the fi rst line

must be fl ashing to enter a target

volume. Use

PRO

to switch between

(Gal/L) and the Numeric value.

Note: Gal/L must be fl ashing for the valve to

operate. Push

CLR

for 3 seconds to

reset the actual volume (the second
line).

First line: Target volume
Second line: Actual volume

Function

Display

Possible Actions

Comments

3.1

Filled

2000 g

Filled

7550 L

CLR

to stop the audible alarm

CLR

for 3 seconds to reset actual volume

(second line)

First line: shows alarm activated (fi lled)
Second line: displays actual volume

When the alarm is activated, the valve
will close until Actual volume is below
the Target volume.

Function

Display

Possible Actions

Comments

Access

Exit

Push

PRO

for 3 seconds

Push

PRO

for 3 seconds

Alarms must be cleared to access pro-
gram mode.

Flow Meter Calibration

P/Gal

150
P/L

98

↑ ↓

to modify value

PRO

for 3 seconds to go back to main screen

Cal # should be located on the fl ow
meter tag

Cal # US = pulses/gallon
Cal # Metric = pulses/liter

2. Generality

3. Functionality

4. Alarms

5. Program

Advertising