Fieldpilot, Discarded hose connection point, Discarded hose connection point q r o – TeeJet FieldPilot Install Ford Versatile 8x6-9x6 User Manual

Page 13

Advertising
background image

www.teejet.com

11

FieldPilot

®

4. PrePare OrBital ValVe

Before installing any hoses, disconnect and discard the Pressure hose between the Pressure Relief Valve

and the Orbital P port. Disconnect the Tank hose from the T port of the orbital and install the

(R)

#16 Run

Tee to this port. Connect the

(Q)

adaptor fitting to the branch of the Tee. Reconnect the Tank hose to

the run of the Tee. Disconnect the hose from the L port. Install

(O)

#10 Run Tee to this port. Reconnect

the hose to the run of the Tee. Disconnect the hose from the R port. Install

(O)

#10 Run Tee to this port.

Reconnect the hose to the run of the Tee.
Note: Additional hose length for the L & R ports may need to be pulled up from the underside of the tractor.
Figure 1-7: Prepare Orbital Valve

Discarded Hose

Connection Point

Discarded Hose

Connection Point

Q

R

O

Advertising