IR Probe Placement

Place a MRIRP over the IR window on a television or other equipment to be controlled. MRIRP must
completely cover IR window and other extraneous light should be blocked with opaque tape. Turn the TV
on manually. If the TV does not respond to "MUTE" or "VOLUME" commands from the transmitter or
wired panel, change the position of the MRIRP.

Preparation for Use

NOTE

The CNTV should be powered from a 12 VDC power pack. Obtaining power from the
power pack and the network does not result in damage to the unit. If system design
prevents use of power pack (i.e., absence of AC outlet) contact a Crestron technical
support representative for power alternatives.

Crestron recommends specific power packs for its network devices. The recommended power pack for
the CNTV is Crestron part number PW-1205. If an external power pack other than this Crestron model is
obtained, verify that it meets the required specifications and polarity as shown in table 3.

Table 3. DC Power Pack Specifications

CRESTRON POWER PACK

INPUT SPECS

OUTPUT SPECS

PW-1205

120VAC 60Hz 18W

12VDC 500mA

DC Power Pack Polarity

Refer to figure 5 for a typical hook-up diagram of the CNTV within a Cresnet system. Connecting cables
and hardware are not supplied with the unit, due to variations of installation requirements. Crestron
recommends that wall jacks with an RJ11 (6-6) receptacle be located in the room with a CNTV. Use a
telephone cable of appropriate length to connect the CNTV to the wall jack. Wire a Cresnet cable to the
four terminals at the rear of the wall jack.

CAUTION

The modular NET port on the CNTV requires unique wiring. Wiring the port according to
Crestron Network Modular Cable Requirements (latest version of Doc. 5682) will
result in damage to the CNTV.

Due to the wire order within the cable, the connecting color scheme is non-standard and illustrated in
Detail A of Figure 5. Local power is provided, so the fourth wire (+24V) is not needed. If a wall jack
connection is not an option, Detail A also illustrates a direct to Cresnet alternative. Detail B provides a
detailed illustration of the communication cable required if a wired panel is employed as an interface.