ThermoWorks RTR-500GSM WIRELESS LAN OR GSM (CELLULAR) LOGGERS User Manual

Page 8

Advertising
background image

5

Clock Settings


This is the screen where you set the RTR-500GSM’s internal
clock. You can set the current time to match your PC or to
another time, for example if you are planning to deploy the unit in
a different time zone. It is important to do this because with
firmware versions 1.03 and below, even if you turn “Set Clock to
Carrier” on, it will only adjust the minutes (for accuracy purposes)
but not the hour (for time zone purposes). This is corrected in
later firmware versions to take the entire time and date from the
carrier.




6

Email Settings


This screen is where you make the settings for the server you will
be using to send Emails for Warnings, Data Downloads or Current
Readings, should you choose to do so. You will need to
determine the type of authentication, if any, required by your
Email server. The RTR-500GSM supports either SMTP
Authentication or POP Before SMTP. For SMTP Authentication
the RTR-500GSM uses the LOGIN protocol. If you are unsure
about this you should check with your Service Provider, your IT
Specialist, or you can try using the “ehlo” command as described
in the appendix at the end of this guide.