Tii 96-00-1 SERIES User Manual

Tii Equipment

Advertising
background image

TII P/N: 92222101

141 Rodeo Drive

tii 96-00-1 SERIES

Edgewood, NY 11717

ADSL POTS SPLITTER MODULE

Customer Service/Sales 888-844-4720

Rev B 07/09

INSTALLATION NOTE














1.0 DESCRIPTION

1.1 The TII 96-00-1 Series ADSL POTS Splitter Module

maintains a constant direct connection between
customer and central office service provider.

1.2 The Splitter Module is equipped with a customer test

jack (see Figure 1). The customer can insert the RJ-11
plug from a working telephone into this test jack to
assure a signal is received from the central office. This
is the only time the customer is disengaged (both DSL
and POTS service) from the central office.

2.0 WARRANTY

2.1 See TII Warranty. If this unit fails during the warranty
period, the factory should be requested to authorize return.
Return the unit prepaid when authorization is received.
Units that fail due to abuse or normal wear should be
discarded.

3.0 INSTALLATION

3.1

INSTALLING ADSL POTS SPLITTER MODULE


3.1.1

Remove the Splitter Module from plastic bag and

inspect; if damaged, replace with an undamaged Splitter
Module.
3.1.2 Hold the Splitter Module with the cover pivot side on
the right. Lower the pivot side edge inside the designated
installation cavity.
3.1.3 Engage the right end ledge under the catch. (See
Figure 2)
3.1.4 Push the left side end down until the latch snaps
closed.


























3.2 SPLITTER MODULE WIRING

3.2.1

Five telephone voice (POTS) pairs and one DSL line

(DATA) can be connected to a single Splitter Module. The
customer has the option of installing a #10 Master lock around the
customer lock hasp (see Figure 1).
3.2.2 When installing the first pair of customer telephone wires,
always begin with the bottom terminating rockers (see Figure 1).

3.2.3 Do not strip wire insulation from wires to be
terminated to Splitter Module.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY,
INSERT A RJ-11 PLUG INTO THE CUSTOMER TEST JACK
PRIOR TO MAKING ANY WIRING CONNECTIONS.


3.2.4

Dress terminating wires (to protector) over NID
divider.

3.2.5

Insert and terminate TIP (GRN) & RING (RED)
wires into sealed IDC station protector (see
protector installation note for further details).

3.2.6

Open customer security cover on Splitter Module.

3.2.7

Lift all Splitter Module rockers to the open
position as shown (see Figure 1).

RING SIDE (RED)

TIP SIDE (GREEN)

LEFT SIDE LEDGE

TIP (GRN) & RING (RED)
TERMINATING WIRES (TO
PROTECTOR)

Figure 2

Figure 1

CUSTOMER TEST JACK

VOICE CIRCUITS ONLY

TEST PORTS

DATA -DSL SIGNAL TO
MODEM

ALL IDC’S ACCEPT 22-26
AWG SOLID WIRE

PIVOT SIDE LEDGE

CUSTOMER LOCK HASP

Advertising