Tii 96-00-4 SERIES User Manual

Tii Equipment

Advertising
background image

TII P/N:

92226901

tii 96-00-4 SERIES

141 Rodeo Drive

ADSL2+ SPLITTER MODULE

Edgewood, NY 11717

TII P/N: 922269

Customer Service/Sales 888-844-4720

Rev B 07/09

INSTALLATION NOTE














1.0 DESCRIPTION

1.1 The TII 96-00-4 Series ADSL2+ Splitter Module
maintains a constant direct connection between
customer and central office service provider. The
Splitter Module is equipped with a customer test jack
(see Figure 1). The customer can insert the RJ-11
plug from a working telephone into this test jack to
assure a signal is received from the central office.
This is the only time the customer is disengaged (both
DSL and POTS service) from the central office.

2.0 WARRANTY

2.1 See TII Warranty. If this unit fails during the

warranty period, the factory should be requested
to authorize return. Return the unit prepaid. Units
that fail due to normal wear or abuse should be
discarded.

3.0 INSTALLATION

3.1 Remove the Splitter Module from plastic bag and
inspect; if damaged, replace with an undamaged
Splitter Module.
3.2 Hold the Splitter Module with the cover pivot side

on right.

3.3 Lower the pivot side edge inside the designated

installation cavity.

3.4 Engage the right end ledge under the catch. (See

Figure 2)

3.5 Push the left side end down until the latch snaps

closed.













4.0 WIRING

4.1 Three telephone voice (POTS) pairs and one DSL

line (DATA) can be connected to a single Splitter
Module. The customer has the option of installing
a #10 Master lock around the customer lock hasp
(see Figure 1).

4.2

When installing the first pair of customer
telephone wires, always begin with the bottom
terminating rockers (see Figure 1).


4.3 Do not strip wire insulation from wires to be
terminated to Splitter Module.

CAUTION: TO REDUCE THE RISK OF PERSONAL
INJURY, INSERT A RJ-11 PLUG INTO THE
CUSTOMER TEST JACK PRIOR TO MAKING ANY
WIRING CONNECTIONS .

4.4 Dress terminating wires (to protector) over NID
divider.
4.5 Insert and terminate TIP (GRN) & RING (RED)

wires into sealed IDC station protector (see
protector installation note for further details).

4.6 Open customer security cover on Splitter Module.
4.7 Lift all Splitter Module rockers to the open position

as shown (see Figure 1).

4.8 Dress wires around customer security cover.
4.9 Start wiring from the bottom left rocker.
4.10 Hold the customer voice telephone wires

between thumb and index finger (approx. 1/8”
separation between wires).

Figure 1

CUSTOMER LOCK HASP

PIVOT SIDE LEDGE

CUSTOMER TEST JACK

DATA ROCKER

VOICE CIRCUITS ONLY

TEST PORTS

ALL IDC'S ACCEPT 22-26 AWG SOLID WIRE

TIP SIDE GREEN

RING SIDE RED

TIP(GRN) & RING (RED)
TERMINATING WIRES
(TO PROTECTOR)

Advertising