INSTALLATION NOTE

1. GENERAL

The tii 760 Universal Network Adapter is
designed to retrofit either a tii 325 or tii 326 one
pair or two pair station protector.

The tii 760 is furnished complete with customer
wiring bridge / RJ-11 modular jack with spade
tipped leads for one pair. The tii 760-2 is
similarly equipped for two pair.

No special tools are required to install or
maintain this product.

The tii 760 is equipped with a cover tab that
allows the customer to lock the unit, but allows
the Telco to override the lock.

The interior has a set of hinged covers that
keep the Telco protector modules and station

electronics out of the customer’s view and
touch. They may be accessed with a

3

/

8

” hex

head terminal wrench or a pin-in-head wrench.

The customer wiring bridge and the RJ-11
modular jack are press fit and readily field
replaceable.

The tii 760 Series Universal Network Adapter is
equipped with four card slots which allow a
variety of station electronics to be fitted to the
customer line.

If the hook up wire or OSP cable is physically
larger than No. 22AWG, a fusing conductor of
No.

22AWG

solid

copper

wire

with

thermoplastic insulation or No. 22AWG copper
clad steel (bridle wire) shall be employed.

2. WARRANTY

See tii Warranty. If this unit fails during the warranty
period, the factory should be requested to authorize

return. Return the unit prepaid when authorization is
received. Units that fail due to abuse or normal wear
should be discarded.

3. INSTALLATION

– PREPARATION

If there are any outboard electronic packages
mounted beside the tii 325 or tii 326 station
protector, they may have to be moved. The tii
760 Series Adapter requires a clear space of two
and one-half inches on both sides and top of the
station protector.

After ensuring that adequate space is available
to mount the tii 760 Adapter, remove and discard
the station protector cover.

Inspect the protector, wiring and ground
connection. Perform any maintenance required
by local practice.

4. INSTALLATION

– NO ELECTRONICS

Carefully remove the inside wires from the
protector and pull them out through the
grommet. Carefully bend them away from the
installation.

Remove the tii 760 Adapter from the box and
inspect if for damage. If the unit is damaged,
obtain another unit.

Using a screwdriver loosen the screw below the
hex head or pin-in-head security screw and open
the outer door. Then with a

3

/

8

” hex head

terminal wrench or a pin-in-head wrench, loosen
the security screw and open the inner door. Pull
down the access door in the center of the unit.

Slide the tii 760 Adapter over the protector base
all the way to the wall. The tii 760 is designed to
fit snugly over the base of the tii 325 and tii 326,
but does not require excessive force to install.

Locate the RED and GREEN spade tipped wires
coming from the RJ-11 jack on the right hand
side and terminate them on the Ring and Tip
terminals of the upper protector module
respectively. Observe polarity.

If the tii 760 Adapter is fitted for two lines, and
the second protector module is in place, locate
the RED and GREEN spade tipped wires coming
from the RJ-11 jack on the left hand side.
Terminate them on the ring and tip terminals of
the second protector module. Observe polarity.