Tii 9600 User Manual

Tii Equipment

Advertising
background image

P/N 92215901 • Rev C• 3/3/2008

Warranty: If this unit fails during the warranty period, contact tii customer service to authorize return. Unit may be returned prepaid.

Model 9600
Outdoor 12-Line Broadband NID

Installation Note

Description

1. This installation note provides the description

and installation steps for the tii 9600 Outdoor
Network Interface. This product is designed
to combine station electronics and network
interface within a single housing.

2. The unit is furnished complete with housing,

protector module(s), RJ-11 jack, customer
wiring bridge(s) for one to twelve lines and
customer instructions.

3. The housing is constructed from rugged heat

and solvent resistant UV stabilized materials.

4. The tii 9600 Outdoor Network Interface is

furnished complete and requires no special
tools for installation or maintenance, except if
ordered with optional pin-in-head security
screw.

5. The unit may be ordered with protection

modules or less protection modules, and may
be ordered with customer wiring bridges for
one to twelve lines.

6. The tii 9600 is provided with two separate side

hinged doors. The outer door has provision
for a padlock. The inner door is held closed
with a recessed hex head security screw to
prevent unauthorized access.

7.

tii’s 9600 Outdoor Network Interface can be
fitted with numerous types of protector
modules (see data sheet for tii 9600 Outdoor
Network Interface).

Installation

1. External mounting ears are provided for

exterior mounting. Mount the 9600 to the wall
using the appropriate hardware and methods.

2. Thread the protector ground wire through the

lower left hand grommet in the base of the unit
and connect it to the ground stud.

3. Run and connect the ground wire to an

approved ground making the run as short and
straight as possible.

4. Thread the drop wire through the same

grommet and connect it to the tip and ring
ports of gel-filled protector module.

5. If a second line is being installed at this time,

repeat step 4.

6. Secure the incoming drop wire and/or riser

tube with a tie wrap or clamp.

7. Close the telco door and tighten the security

screw until it is snug.

8. Feed the station wire through the lower right

hand grommet in the base of the unit and
terminate the tip and ring on the appropriate
binding posts of the customer bridge module
for Line 1.

9. Repeat step 8 if additional lines are being

installed.

10. Inspect work for shorts, grounds and broken

wires.

11. Close and snap secure the customer bridge

module cover, making certain that it is properly
seated, then close the outer door and secure it
by tightening the screw.

Advertising