tii P/N: 92214101

141 Rodeo Drive

tii 83

Edgewood, NY 11717 Customer Bridge Module
Toll Free 888.844.4720

With Auto-Jack

®

RJ-11 Jack

www.tiinettech.com

01/08 Rev B

INSTALLATION NOTE

BASIC OPERATION

Inserting RJ-11 Plug automatically disconnects
customer equipment and connects to central office.
This operation is usually performed during testing of
the telephone line.

By removing RJ-11 plug, customer is automatically
connected to central office. This is the normal
operating mode.

INSTALLING CUSTOMER BRIDGE MODULE

Insert hinge side of module under tab on enclosure.
Dress wires to telco compartment. Pull back retainer
tab, push down module until it snaps in place.
Release retainer tab to hold module firmly in place.

CONNECTING CUSTOMER WIRING

NOTE: The two Tip (Green) and the two Ring (Red)
screws are electrically connected together to provide
increased inside wire connections.

A maximum of 4 telephone wires can be attached to
each wiring bridge screw. Insert wire through
grommet. Strip insulation from wire. Pass wires

behind

hinge

pin.

Connect

wire

to

color

corresponding terminals. (NOTE: If customer wiring
colors do not match Green and Red, inspect the first
jack in premise. Determine which wire colors
connect to Green and Red in jack.)

Connect same wire colors to Green and Red
terminal

screws

on

this

module.

(Example:

White/Blue stripe to Green; Blue/White to Red).
Wrap each clockwise between a washer on screw.

Insure excess wire ends are wrapped tightly around
screw. Tighten screws snugly. Tuck excess wire in
trough. Additional wires should be coiled and stored
in trough. Perform customary tests. Close and snap
cover securely. (NOTE: Use a Mater

®

Lock #10 or

equivalent (sold in local stores) when it is desirable
to lock individual covers.)

TESTING PHONE LINE

(CAUTION: INSERT A PLUG INTO TEST JACK
PRIOR TO ANY WIRING CHANGES)

Plug a working phone directly into the test jack.
WAIT ONE MINUTE. Lift receiver. If problem goes

*RJ11 Plug is not required for normal operation

Customer Security Cover

Customer Test Jack (Auto-Jack

TM

)

Customer Lock Hasp

Customer Premise Connections