Tii 96-00 User Manual

Tii 96-00

Advertising
background image

tii 96-00

141 Rodeo Drive

Customer Bridge Module

Edgewood, NY 11717

TII P/N: 92211801

Customer Service/Sales 888-844-4720

Rev B 05/09

INSTALLATION NOTE















BASIC OPERATION

The TII 96-00 Module maintains a constant direct
connection between customer and central office service
provider. The Module is equipped with a customer test
jack (see Figure 1). The customer can insert the RJ-11
plug from a working telephone into this test jack to assure
a signal is received from the central office. This is the only
time the customer is disengaged from the central office.

INSTALLING CUSTOMER BRIDGE MODULE (CBM)

• Remove the Module from plastic bag and inspect; if

damaged, replace with an undamaged Module.

Hold the Module with the cover pivot side on right.

• Lower the pivot side edge inside the designated

installation cavity.

• Engage the right end ledge under the catch. (See

Figure 2)

• Push the left side end down until the latch snaps

closed.

CUSTOMER BRIDGE MODULE WIRING

• Four telephone voice (POTS) pairs can be connected

to a single CBM. The customer has the option of

installing a #10 Master lock around the customer lock
hasp (see Figure 1).

• When installing the first pair of customer telephone

wires, always begin with the bottom terminating
rockers (see Figure 1).

• Do not strip wire insulation from wires to be

terminated to the CBM.

CAUTION: TO REDUCE THE RISK OF PERSONAL

INJURY, INSERT A RJ-11 PLUG INTO THE
CUSTOMER TEST JACK PRIOR TO MAKING ANY
WIRING CONNECTIONS.

• Dress terminating wires (to protector) over NID

divider.

• Insert and terminate TIP (GRN) & RING (RED) wires

into sealed IDC station protector (see protector
installation note for further details).

Open customer security cover on CBM.

• Lift all Module rockers to the open position as shown

(see Figure 1).

Dress wires around customer security cover.

Start wiring from the bottom left rocker.

• Hold the customer voice telephone wires between

thumb and index finger (approx. 1/8” separation
between wires).

NOTE: Wires should be aligned to the corresponding

holes. Green wire to the “T” (GRN) labeled wire guide
and the Red wire to the “R” (RED) labeled wire guide.

• Insert wires into wire guides at the same time until

they bottom out.

• While holding wires in wire guides, terminate rocker

with thumb (lower rocker all the way).

Figure 1

Figure 2

Top Left Terminating Rockers

Wire Guides Tip & Ring

Bottom Terminating Rockers

Customer Lock Hasp

Pivot Side Ledge

Customer Test Jack

Test Ports

Ring Side (Red)

Tip Side (Green)

Tip (Green) & Ring
(Red) Terminating
Wires (To Protector)

Advertising