INSTALLATION NOTE

1. GENERAL

The tii ELP-2 (External Line Protector) has been
designed to provide superior surge protection to
the single family and multi-

family ONT’s (Optical

Network Terminals).

The ELP-2 protection module is connected
between the customer wiring pairs and the ONT
telephone RJ-11 jack outputs. See Figure below
for product features. Any surge originating from the
customer premises is blocked and diverted to the
ground.

The ELP-2 has multi stage protection for
superior surge protection to the ONT.

The ELP-2

’s modular design permit’s installation

of additional devices in an integrated fashion.

2. WARRANTY

See tii Warranty. All units are completely
encapsulated and are not repairable. If this unit
fails during the warranty period, the factory should
be requested to authorize return. Return the unit
prepaid when authorization is received. Units that
fail due to abuse or normal wear should be
discarded.

3. INSTALLATION

Remove the ELP-2 from the packaging and
inspect it, if defective, see warranty above.

The ELP-2 is equipped with a mounting flange
slot on the top, secure to flat surface near ONT
using a # 8 Philips screw. Mounting can be also
be accomplished using a double sided tape or
Velcro.

The unit is supplied with a #10 and #22 AWG
ground wire. Connect the #10 ground wire to the
main ground in the ONT. Connect the #22
ground to the shield of the fiber cable using
standard bonding connectors.




















tii

– ELP-2

MOUNTING SLOT

10AWG GROUND WIRE

22AWG GROUND WIRE

MDU PROTECTED OUTPUT

CUSTOMER RJ-11 INPUT

GROUND LUG

MALE MODULE INTERFACE

FEMALE MODULE INTERFACE

CUSTOMER RJ-11 INPUT

MDU PROTECTED OUTPUT