INSTALLATION NOTE

1. DESCRIPTION
1.1 The tii SVM-4 Series Multi-Line Switchable

Voice Module is used when porting existing
telephone numbers.

1.2 The tii SVM-4 has been designed to provide

automatic switching of a customer’s
telephony provider from Telco to Digital
Voice Service automatically after installation
when the number is ported.

1.3 The tii SVM-4 can come equipped with an

optional secondary telephone line surge
protection to enhance the Digital Phone
service reliability.

1.4 The SVM-4 should only be used for indoor

applications, if mounting outdoors the SVM-4
should be mounted in a weatherproof
housing.

1.5 The SVM-4 is powered from the Digital Voice

Service line, and switches to Digital Voice
Service after validating telephone ringing
voltage presence on this line. The green
LED will blink slowly when the SVM is
receiving power from the Digital Voice
Service Line.

1.6 The SVM-4 may be reset by using the reset

push button accessible on the side wall of
the device. The SVM-4 must be powered by
the ATA / EMTA for the reset function to
operate.

1.7 IDC rockers are used to terminate 26-22

AWG solid wire.

2. WARRANTY

2.1 See tii Warranty. If this unit fails during the

warranty period, contact tii customer service
to authorize return and return the unit
prepaid. Units that fail due to normal wear or
abuse should be discarded.

3. INSTALLATION (Line 1)

3.1 Remove the unit from the bag and

inspect it for damage. If damaged, obtain
another unit.

3.2 Locate a suitable flat, dry area to install

the unit.

3.3 Prior to installing the SVM-4 pre-drill the

(3)

mounting

location

holes

to

accommodate #8 self tapping screws
(See Figure 1).

3.4 Lift the blue rocker for the digital voice

service wires (MTA) to the full up
position. DO NOT strip wires. (See Figs
2 & 3)

3.5 Insert the Digital Voice Service wires

from

ATA/EMTA

into

wire

guides

simultaneously until they bottom-out.
While holding the wires in position,
terminate them into the MTA (Blue)
rocker by lowering it to the full DOWN
position. (See Figs 2 & 3) If the
ATA/EMTA is supplying power to the

SVM-4-0