Tii 67 Series User Manual

Tii Equipment

Advertising
background image

TII P/N: 92214301

141 Rodeo Drive

tii 67 Series

Edgewood NY11717

Sealed Wire Termination Block

Toll Free 888.844.4720
www.tiinettech.com

Rev B 02/08

INSTALLATION NOTE

1.00 GENERAL

1.01 The TII 67 Series Sealed Wire Termination

Block

is

used

where

several

parallel

connections to a single tip-ring pair are
needed. The TII 67 Series provides parallel
connections in the following configurations:

Model # Description
67-1

1-pair input, 3 parallel pair outputs

67-2

2-pair inputs, 2 parallel pair outputs

1.02 Installation is accomplished using standard

technician tools. The Insulation Displacement
Contacts (IDC) are achieved using gel sealed
rockers.

2.00 INSTALLATION

2.01 Remove the TII 67 Sealed Wiring Terminal

Block and inspect it for damage. If damaged,
obtain another unit.

2.02 Locate a suitable flat, dry area to install the

unit. Use one size #8 screw to mount the unit.

2.03 The TII 67 Sealed Wiring Terminal Block can

also be installed in the TII 164 enclosure.

2.04 Lift the rocker of the input terminal (L1 or L2)

to the full up position. DO NOT strip wires.
Hold the wire pair to be terminated between
thumb and index finger. Insert wires into wire
guides simultaneously until they bottom-out.
While holding wires in position, terminate
rocker by lowering to the full DOWN position.

2.05 Terminate any additional input or out pairs as

required following the above steps.

2.06 To keep wire pairs organized, route them

through the molded wire looms as shown in
Figure 1.

Figure 1

TII 67-1

TII 67-2

T

R

T

R

T

R

T

R

INPUT

OUTPUTS

L1

T

R

T

R

INPUT

OUTPUTS

T

R

T

R

L1

L2