Tube Stage:


Typical Distortion: 1% to 10%, depending on “Drive” level, predominately
second harmonic.

Noise: -80dBu (22Hz to 22KHz), output gain @ 0dB.

Metering:


Tube “Drive” LED: Variable intensity over 10dB level range, typically corresponding
to 1% to 5% THD.

Tube “Peak” LED: Dependant on level and drive, typically corresponding to 10%
THD.

Output “Peak” LED: +19dBu on output.

VU Meter: Switchable to Channel 1 or 2, and Input or Ouput.

Nominal calibration: 0VU = +4dBu.

+10dB switch calibration: 0VU = +14dBu.

Power Requirements:


Internally set to 230V 50Hz or 115V 60Hz operation,

Detachable IEC power cord,

Power consumption 34VA.

Dimensions:


2U, rack mounting or free-standing.

W x H x D = 483mm x 88mm x 200mm (19.0” x 7.9” x 3.5”), behind front panel.

Shipping weight: 6Kg.

The above specifications are typical values, and do not represent limits for any particular unit.

These specifications are subject to change without notice.