Specifications – Toa DA-250FH CU User Manual

Page 22

Advertising
background image

22

* 0 dB = 0.775 V

Note: The design and specifications are subject to change without notice for improvement.

Power cord (2 m or 6.56 ft) .................................................. 1
Removable terminal plug (3 pins) ........................................ 4
Tamper-proof cap ................................................................ 4

• Accessories

120 V AC, 50/60 Hz

Class D

200 W (based on UL/CSA standards)

1300 W (rated output 4 Ω x 4)

850 W (rated output 8 Ω x 4)

4 circuits, +4 dB* (1.23 V, input level control in maximum position),
10 kΩ, electronically-balanced, removable terminal block (3 pins)
CH 1 mode ON/OFF switch (ON: CH 1 to All ch, OFF: Each ch)

4 channels: 250 W x 4 (4 Ω), 170 W x 4 (8 Ω)
2 channels (BRIDGE): 500 W x 2 (8 Ω)
M4 screw terminal, distance between barriers: 8.8 mm (0.35")

20 – 20,000 Hz (±1 dB)

0.1% (1 kHz), 0.3% (20 – 20,000 Hz)

Protection against excessive current flow due to overload,
short circuit, unusual DC voltage output,
temperature rise at power amp. heat sink (over 110°C or 230°F),
temperature rise inside the unit (over 80°C or 176°F)

100 dB (A-weighted)

70 dB (A-weighted)

Power (blue) x 1, Input (green) x 4, Output (yellow) x 4, Peak (red) x 4,
Protect (red) x 4

Forced air cooling

–10°C to +40°C (14°F to 104°F)

Under 90% RH (no condensation)

Panel: Aluminum, black, alumite
Case: Plated steel sheet

482. (w) x 44 (h) x 401.8 (d) mm (18.98" x 1.73" x 15.82")

6.6 kg (14.55 lb)

Power Source

Amplification system

Power Consumption

Input

Rated Output

Frequency Response

Total Harmonic Distortion

Protection Circuit

S/N Ratio

Crosstalk

LED Indicator

Cooling

Operating Temperature

Operating Humidity

Finish

Dimensions

Weight

16.1. DA-250F CU

16. SPECIFICATIONS

Advertising