8.3. Removable Terminal Plug Connection

Be sure to use the supplied removable terminal plugs for connections to the removable terminal blocks.

Cautions
• Be sure to use shielded cables for audio signal lines.
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• Use cables of AWG 12 – 24.

Solid or stranded cable

Shielded cable

7 mm

(0.28”)

7 mm

(0.28”)

20 mm

(0.79”)

[Cable end treatment]

[Connector connections]

Step 1. Loosen the terminal screw, then insert the cable.

Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.)

Tip
Recommended slotted screwdriver type: Screwdriver with 3 mm (0.12") blade width

Tightens

Loosens

Terminal screw

Slotted screwdriver

Shielded cable

Removable terminal plug (accessory)