INSTALLATION GUIDE FOR VP-1061/1121/1241/1361 POWER AMPLIFIERS

This guide describes how to install the YA-1000A Fault Detection Circuit Module into the power amplifier
noted above.
Leave all these works to a qualified electrician.
Do not pass this guide to users.

For Service Technicians Only

Disconnect the unit's power source before starting work.
Doing otherwise may cause electric shocks.

WARNING

Never touch the knockout panel's cut edge to prevent injury.

CAUTION

MOUNTING THE YA-1000A FAULT DETECTION CIRCUIT MODULE

133-22-224-70

URL: http://www.toa.jp/

For the connection and functions of the YA-1000A, refer to the instruction manual enclosed with the YA-
1000A.

B

A

SW201

Cut off with nippers. (4 places)

Cable tie

Knockout panel

Step 1. Check to be sure that the YA-1000A's

SW201* switch is set to the "A" position.
* Factory preset to the "A" position.

Step 2. Using nippers, cut off the knockout panel

(specified 4 places) for Fault detection
module slot in the power amplifier's rear
panel.
As the intermediate connector is tied to the
knockout panel's back side, cut the cable tie,
then pull out the intermediate connector.

Step 5. Insert the YA-1000A into the module slot on

the power amplifier, then secure it with 2
tapping screws 3 x 8 supplied with the YA-
1000A.

Step 3. Disconnect the junction cable connected to

the YA-1000A and the jumper connector
plugged into the amplifier's intermediate
connector.

Note: The removed cable and connector are

not used.

Step 4. Plug the amplifier's intermediate connector

into the YA-1000A's intermediate connector.

Disconnect

Disconnect

YA-1000A

Module slot

Junction cable
(not used)

Intermediate
connector

Intermediate
connector

Jumper connector
(not used)

Plug

3

3

4

Mounting