Removable terminal plug connection – Toa D-2000 Series Installation User Manual

Page 35

Advertising
background image

Model Number

a

1

l

1

l

2

AI 1,5-8 BK

AI-TWIN 2 x 1,5-8 BK

6.6 (0.26)

a

2

3.6 (0.14)

14 (0.55)

16 (0.63)

2.3 (0.09)

8 (0.31)

8 (0.31)

a

3.4 (0.31)

Unit: mm (in)

b

1.8 (0.07)

Model Number

a

l

1

l

2

AI 0,34-8 TQ

AI 0,5-8 WH

2 (0.08)

Unit: mm (in)

2.5 (0.1)

12.5 (0.49)

14 (0.55)

8 (0.31)

8 (0.31)

b

0.8 (0.03)

1.1 (0.04)

35

4.3. Removable Terminal Plug Connection

Notes
• Avoid soldering stranded or shielded cable, as contact resistance may increase when the cable is tightened

and the solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• When connecting 2 cables or a shielded cable to a single terminal,

use a ferrule terminal with an insulation sleeve to crimp the cables
because such cable conductors could become loose.

Recommended ferrule terminals for signal cables
(made by Phoenix Contact)

Recommended ferrule terminals for power supply cables
(made by Phoenix Contact)

Crimping tool: CRIMPFOX UD6-4 (made by Phoenix Contact)

Wiring procedures

Step 1. Wiring the supplied removable terminal plug.

1-1. Loosen the terminal screws to insert the wire.

1-2. Tighten the terminal screws.

Ensure that the wire does not break free when
pulled. If the wire does pull free, repeat the
connection procedure from the start.

Step 2. Insert the wired terminal plug into the

corresponding terminal block in the unit's rear
panel.

Note
Do not reverse Steps 1 and 2 above. Force is applied
to the connected receptacle pins while tightening the
terminal screw and they may be damaged, resulting in
bad connector contact.

Solid cable and stranded cable

Shielded cable

7 mm*

(0.28'')

(0.28'')

(0.59'')

7 mm*

15 mm

Terminal screw

Removable terminal plug

Slotted screwdriver

Tightens

Loosens

Bit shape 3 mm

Tip
Recommended slotted screwdriver type:
Screwdriver with blade that is 3 mm (0.12'') in width

(0.12'')

Cable sheath to trim

Insulation sleeve

Contact section

Insulation sleeve

Contact section

a

l

2

a

1

a

2

l

1

l

2

l

1

b

b

* Expose 8 mm (0.31'') or more when using

the above ferrule terminal, and cut off an
extra conductor protruding from the sleeve.