Toa ZM-9002 User Manual

Zone managers, Operating instructions, General description

Advertising
background image

ZONE MANAGERS

OPERATING INSTRUCTIONS

ZM-9001, ZM-9002

Thank you for purchasing TOA's Zone Manager.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

1. GENERAL DESCRIPTION

The ZM-9001 is a remote control switch panel used with the 9000 Series amplifiers.
It adds 6 control inputs and can be mounted in a 1-gang electrical box (American type).
The ZM-9002 is a remote control switch/volume panel used with the 9000 Series amplifiers.
It adds 4 control inputs and 1 volume control, and can be mounted in a 1-gang electrical box
(American type).

2. NOMENCLATURE AND FUNCTIONS

2.1. ZM-9001

[Front]

[Rear]

1

3

5

2

4

6

E

OUT

1

2

1. Control buttons [1 – 6]

Activate the function assigned to them when
pressed.

2. Control output terminal [E, OUT]

Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.

2.2. ZM-9002

[Front]

[Rear]

1

3

2

4

0

E OUT

3

4

5

3. Control buttons [1 – 4]

Activate the function assigned to them when
pressed.

4. Volume control

Adjusts the volume on the assigned input or
output channel.

5. Control output terminal [E, OUT]

Connect this terminal to the 9000 Series
amplifier's REMT VOL terminal.
Use a shielded cable with 50 Ω or less line
resistance (per line) for this connection.
Avoid installation of this cable and power cables
in the same conduit. Separate piping.

3. CONNECTIONS

Connecting the ZM-9001 Zone Manager to the 9000 Series amplifier adds 6 control inputs and
allows the equipped 6 control buttons to perform the functions assigned for input's or output's
channel volume up/down, or other functions.
Connecting the ZM-9002 Zone Manager to the 9000 Series amplifier adds 1 volume control and 4
control inputs. Volume of the input or output channels can be remotely adjusted with the volume
control, and the 4 control buttons can be assigned the same functions as those of the ZM-9001.
Function assignment to the control buttons or volume control is performed at the 9000 Series
amplifier. For the method, refer to the instruction manual supplied with the 9000 Series amplifier.

E

E

4

4

3

3

1
2

2

1

VOL2

REMT

VOL1

REMT

OUT

IN

I/O

CTRL

E

IN

E

IN

REMT VOL1

(Remote volume 1)

REMT VOL2

(Remote volume 2)

IN

E

IN

E

OUT

ZM-9001

E

1

2

3

4

5

6

1

2

3

4

Volume control

ZM-9002

OUT

E

REMT VOL terminal

9000 Series amplifier

Note
One ZM-9001 or one ZM-9002 can be
connected to each of the REMT VOL1 and
2 terminals.

Advertising
This manual is related to the following products: