18

[Bottom]

9. Lithium-ion battery compartment

Install only a dedicated BP-900 Lithium-Ion

Battery in this compartment.

10. Unit address number setting switch

Set the unit address number (001 – 192), taking

care to ensure that the same number is not

duplicated in the system.

If the number [000] is assigned to a unit, the user

of that unit cannot speak. However, the unit can

be used for monitoring.

Set a numeral for the ones place and tens place.

Set this switch to OFF to set the hundreds place

to “0” and to ON to set it to “1.”
Note

This number is factory-preset to [000].

100

10

1

NOT USE

UNIT ID

ON

1

2

10

9

Remove the cover on the bottom side of the unit to expose its setting switches.

Note

The label describing the setting switches is shown

in the following figure.

signal access to this part of the unit, as this would

prevent the unit from transmitting or receiving its

required infrared signal.

5. Voting keys (TS-902 only)

Use these keys to start, end, and cast voting. The

voting status indicator is provided on each key.

6. Speech indicator

Remains lit while the microphone is in use (during

speech). The indicator flashes when the unit is out

of the communications service area.

7. Talk key

When this key is pressed, both the Microphone In-

Use indicator (3) and the Speech indicator (6) light,

and the microphone turns on. Pressing this key

again turns off both indicators and the microphone.

8. Power indicator

Lights when the power is switched ON.

This indicator also flashes when the battery level

is low or the unit is outside the communications

service area.