PRECAUTIONS FOR USE OF THE INFRARED CONFERENCE UNIT

Depending on production date, 2 versions of Infrared conference units (TS-901/902/801/802) that differ in

specification are used in the Infrared Conference system, even though they have identical model numbers.

Since setting methods and other points may differ in part between the 2 versions (having the same model

number), please keep the following instructions in mind when using the Conference units.

1. Identifying Units Based on TOA Logo Position

[If the TOA logo is located on the right]

[If the TOA logo is located on the left]

TS-910 Series instruction manual descriptions are

not applicable in terms of the operations described in

the following sections.

Top view of the Conference unit

Please use the unit as described in the TS-910

Series instruction manual.

Top view of the Conference unit

2. Setup and Operation of Units Having the TOA Logo on the Right

Units with right-side logos differ from units with left-side logos in the following specific areas:
2.1. Unit number settings
The usable unit number is limited.

Using the Unit address number setting switch located at the bottom

of the unit, set the unit number within the range shown in the following

table. The unit will not operate if its assigned number is not within the

valid range.

Model No.

Usable Unit Number Range

TS-901 and TS-902 01 – 96 (00 when used only for monitoring)

TS-801 and TS-802 01 – 64 (00 when used only for monitoring)

2.2. Fixed PTT priority speech operation (TS-901 and TS-801 only)
These models have no Priority speech key operation setting switch.

The Priority speech key is physically limited to PTT operation,

therefore priority speech can only be enabled while the Priority

speech key is held down.

2.3. Monitor volume adjustment
The Monitor volume control is only located on the right side of the

base of the unit.

The sound output of headphone terminals located on both sides of

the unit and the monitor speaker can be simultaneously adjusted

with this Monitor volume control.

UNIT ID

1

10

Unit address number

setting switch

(Setting switch label

shown in the figure.)

Bottom of

Conference unit

Inside cover

Priority speech key

Speech only possible

while key is held down.

HEADPHONES

MAIN SUB

POWER

ON

OFF

HEADPHONES

MAIN SUB

Right side of Conference unit

Monitor volume control