11.4. Mounting the Infrared Transmitter/Receiver Unit

11.4.1. Ceiling mounting

83.5 mm

ø68 ±5 mm

Mounting plate
(supplied with the TS-905/-907)

Coaxial cable

Mounting screw

Infrared transmitter/receiver
TS-905/-907

Tabs (3 places)

Rotate to fix.

1

2

3

The screws supplied with the TS-905 and TS907
are used for mounting it to the microphone stand.
(Refe

r to the next page.)

Mounting screws for ceiling or w

all are not supplied

with the unit. Prepare them separately.

Notes

Step 1. Make a 68 mm diameter hole in the ceiling.

Step 2. Attach the supplied mounting plate to the ceiling panel.

Notes
• Since the distance between two mounting screw holes is 83.5 mm, the plate can also be mounted

over an electrical box.

• For open wiring, use of an electrical box is recommended.
• When attaching the plate to an electrical box, use an L-shaped BNC plug or L-shaped conversion

connector.

Step 3. After wiring completion, mount the Infrared Transmitter/Receiver unit to the mounting plate.

With the unit's tabs (3 places) aligned with each corresponding notch in the mounting plate, rotate the
Infrared Transmitter/Receiver unit clockwise till it stops and fits into place.