6

L

R

L

STEREO BUS

MONO 1 (2)

SWITCH

MONO 1 (2)

BUS

R

STEREO OUT

MONO 1 (2) OUT

[Factory default setting]

[After the change]

L

R

L

STEREO BUS

MONO 1 (2)

SWITCH

ST SUM

MONO 1 (2)

BUS

R

STEREO OUT

MONO 1 (2) OUT

Change in setting

6. INTERNAL SwITCh SETTINGS

11

12 13

14 15

16 17

18

19

[Rear]

11. AC inlet

Connect the supplied power cord.

12. Functional earth terminal

Hum noise may be generated when external

equipment is connected to the unit. Connecting

this terminal to the functional earth terminal of the

external equipment may reduce the hum noise.

Note: This terminal is not for protective earth.

13. Monaural output jacks

Function as sum output for the stereo output

channel by the internal switch setting. (Refer to

section "6. INTERNAL SWITCH SETTINGS.")

14. Stereo output jacks

15. Recording output jacks

Output the signal from the stereo output bus for

recording.

16. Monaural sub-input terminals

Signals from these terminals are sent to each

monaural output bus (Mono 1 and Mono 2).

17. Stereo sub-input terminals

Signals from these terminals are sent to stereo

output bus. Connecting the signal to only "L"

permits it to be input to both "L" and "R."

18. Stereo input terminals (3 – 6)

Only CH6's RCA jacks are internally connected in

parallel to phone jacks.

19. Monaural input terminals (1, 2)

Select either MIC or LINE for connection. If both

are connected, LINE input takes precedence.

The functions below can be made available by changing the switch settings inside the unit.

(1) "PAD" switch: Set to the "IN" position to insert PAD (20 dB) in the monaural input (microphone input).
(2) "HPF" switch: Set to the "IN" position to insert High pass filter (300 Hz, –6 dB/oct) in the monaural input.
(3) "GND" switch: When the unit is connected to external equipment, a ground may create a loop, potentially

generating a noise (hum). In such cases, set this switch to the LIFT position to cut off the ground loop.

(4) "MONO1" and "MONO2" switches: Set to the "ST SUM" position to change each monaural output to stereo

sum output for the stereo output channel.

This work should only be performed by a qualified professional

electrician. If users open the unit case or modify the unit, this may

cause fire or electric shock.

wARNING