Connections 6. specifications – Toa N-8640SB User Manual

Page 4

Advertising
background image

5. CONNECTIONS

6. SPECIFICATIONS

Power Source

Power supply device that complies with IEEE802.3af standard or 12 V DC (supplied from the AC adapter)

Power Consumption

Use of the AC adapter (12 V DC): 3.5 W (station only), Use of the PoE (48 V DC): 5 W

Speech Method

Hands-free conversation

Audio Frequency Range

300 Hz – 7 kHz

Hands-free

Speaker: 3.5 cm cone-type, maximum output 0.5 W, 8 Ω

Microphone: Omni-directional electret condenser microphone

Control Input

1 channel, no-voltage make contact input, open circuit voltage: 5 V DC, short-circuit current: 10 mA or less,

unterminated ends

Control Output

Open collector output, 4 channels, withstand voltage: 30 V DC, control current: Max. 50 mA (4 output 1 COMMON),

unterminated ends

Relay contact output, 1 channel, withstand voltage: 30 V DC, control current: Max. 500 mA, unterminated ends

External Speaker Output Maximum output 0.5 W, 8 Ω, unterminated ends

Network Section

Network I/F:

Network Protocol:

Audio Packet Transmission System:

Number of Paging Destinations:

LAN Connector:

Voice Sampling Frequency:

Quantifying Bit Number:

Voice Encoding Method:

Voice Packet Loss Recovery:

Audio Delay Time:

10BASE-T/100BASE-TX (Automatic-Negotiation)

TCP/IP, UDP, HTTP, RTP, ARP, ICMP, IGMP

Unicast, Multicast

0 Note: Reception only

RJ-45 connector (PoE compatible)

16 kHz, 8 kHz (controllable on the software)

16-bit

Sub-band ADPCM, Cryptosystem

Silence insertion

80 ms, 320 ms (controllable on the software)

Operating Temperature

–10 to +50℃

Operating Humidity

Under 90 % RH (no condensation)

Dimensions

79 (w) x 134 (h) x 53 (d) mm (Complete assembly of parts)

Weight

350 g (Total weight)

Optional Products

AC adapter: AD-1210P or AD-1215P

Note: The design and specifications are subject to change without notice for improvement.

To network

Note:

To AC mains

AC adapter*

Power cable

LAN coupler

N-8640SB

Ext. power supply

Control OUT (BLU)

Control OUT (BLU)

Relay

Diode

24 V DC
GND

+

-

[Example 2] (When using a 24 V DC relay)

[Example 1]

[Example 3]

LAN connection

cable

Frame

ground

Be sure to ground the N-8640SB's frame ground terminal.

Also ground the electrical box if used.

A straight through

cable of UTP

category 5 or more

An electronic lock

or other external

equipment
A switch, sensor,

or other external

equipment
Ext. speakers

(8 Ω, 0.6 W or more)

Max. OUT 0.5 W

Example 1

Example 2

Example 3

Control OUT 1

Open collector OUT
Withstand voltage: 30 V DC

Max. control current: 50 mA

No-voltage closed contact IN

Open voltage: 5 V DC

Short-circuit current: 10 mA or less

Ext. connection cables

Specifications

Connected device Reference

Speaker cable

Control IN COM
Speaker cable

Control OUT

Control OUT COM

Control OUT 4

Control OUT 3

An indicator or other

external equipment

Control OUT 2

Control IN HOT

Control OUT

BRN

Color

BLK

WHT
BLK

BLU

PUR

YEL

ORG

RED

GRY

BLU

Control IN COM (WHT)

Control IN HOT (GRY)

Control OUT 1 (BRN)

Battery etc.

Max.30 V DC

Max. 50 mA

Control OUT COM (PUR)

HOT

COM

Ext. connection cables

(Shown at right.)

Connecting the station to a PoE (Power over Ethernet)

switching hub compliant with IEEE802.3af eliminates

the need for an AC adapter.

Use the AC adapter

AD-1210P/1215P (optional)

or the equivalent.

As for the usable adapter,

consult your TOA dealer.

*

Relay contact OUT
Withstand voltage: 30 V DC

Max. control current: 500 mA

URL: http://www.toa.jp/