Dimensional diagram specifications – Toa C-BC200K User Manual

Page 4

Advertising
background image

Under 20 kg

Maximum wind velocity: 60 m/s (When C-CH200 or C-CH100 series and C-PH200 are used)

Outdoors (except seaside and industrial districts where the unit is subject to corrosion, and

heights that expose the unit to strong wind pressure)

Stainless steel, off white, paint

2.8 kg

Motorized Pan/tilt Head

: C-PH200, CC-5521

Housing Fixing Stand

: C-BC200H

Permissible Load

Wind Load

Application

Finish

Weight

Option

Unit: mm

288

405

475

200

228

70

174

70

30

11

142

313

121

185

150

20

15

142

4-M8 threaded holes
(for mounting the pan/tilt head)

4-M6 threaded holes
(for mounting the Housing Fixing Stand)

2-10.5 x 15 oval holes
(for M8, M10 or W3/8 anchor bolt)

DIMENSIONAL DIAGRAM

SPECIFICATIONS

The unit’s specifications and external view are subject to change without notice.

Accessories
M8 x 30 hexagonal head bolt ............................................ 4
M8 spring washer .............................................................. 4
M8 plain washer ................................................................ 4

133-12-871-0A

URL: http://www.toa.jp/

Advertising