Toa VS-900 User Manual

Page 10

Advertising
background image

10

7.2. Equipment Functions

VS-900MF Main Frame

The VS-900MF accommodates the following cards: Up to 2 VS-900MS or VS-900AL Cards (both cards may
be mixed), up to 4 VS-900RS or VS-910RS Cards (both cards may be mixed), 1 VS-900CO Card, 1 VS-
900AF Card, and 1 VS-900TI Card.
The Main Frame has 2 RS-232C ports; one for programming and the other for operation log output.

VS-900MS Master Station Interface Card

The VS-900MS is used for master station connection. Up to 2 master stations can be connected per card,
and an external recording device can be connected to each line.

VS-900AL Telephone Interface Card

The VS-900AL is used for connecting telephone sets (in compliance with the FCC Regulation Part 68). Up to
2 telephones can be connected per card, and an external recording device can be connected to each line.

VS-900RS Substation Interface Card

The VS-900RS is used for substation connection. Up to 16 substations can be connected per card. The
Substation Interface Card has 2 speech links, one of which also functions as a paging link with the paging
input/output connected to an external amplifier.

VS-910RS Substation Interface Card

The VS-910RS is used for connecting full-duplex substations and option handsets. Up to 16 substations can
be connected per card. The Substation Interface Card has 2 speech links, one of which also functions as a
paging link with the paging input/output connected to an external amplifier.

VS-900CO Outside Line Interface Card

The VS-900CO is used for outside line connection. Up to 2 outside lines can be connected per card, and an
external recording device can be connected to each line.

VS-900AF Audio Function Card

The VS-900AF enables Conference, External Amplifier Paging, and External Source Distribution functions.
The Audio Function Card has 1 conference link (maximum 4 stations), 1 audio output and 16 control outputs
for external amplifier paging, and 1 audio input and 4 control inputs for external source distribution.

VS-900TI Tie-Line Interface Card

The VS-900TI is used to interconnect multiple exchanges. The Tie-Line Interface Card can connect up to 4
links made up by 1 pair of data lines and 2 pairs of voice lines.

VS-900SC Site Connector

When tie-line connecting VS-900 system exchanges, fiber optic cables can be used to extend the audio line
longer than the maximum distance* possible using twisted pair cable. TOA's VS-900 Site Connector is used
to connect the VS-900 system exchanges to the fiber optic interface as shown in the following figure.
* 1.5 km when an AWG20 twisted pair cable is used.

PU-200 Power Transformer Unit

The wall-mountable PU-200 has 2 20V/2.5A AC outputs. One PU-200 unit is required when up to 2
VS-900RS Cards are installed, and 2 PU-200 units are required when 3 or more VS-900RS Cards are
installed.

YC-303 Main Frame Wall Mounting Bracket

The YC-303 is used when mounting the main frame on the wall.

PN-100B Rack Mount Panel

The PN-100B provides side-by-side rack mounting capability for up to 2 PU-200 transformer units.

MS-900 Master Station

The MS-900 can make calls to or receive calls from the substation. It utilizes 2 pairs of twisted cables.

RS-150 Substation (Indoor Type)

The RS-150 can call and converse with the registered master stations. It utilizes a single-pair shielded cable.