Wall mounting – Toa RS-481 User Manual

Page 2

Advertising
background image

Traceability Information for Europe (EMC directive 2004/108/EC)

Manufacturer:

TOA Corporation
7-2-1, Minatojima Nakamachi, Chuo-ku, Kobe, Hyogo, Japan

Authorized representative:

TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg,Germany

133-21-949-80

URL: http://www.toa.jp/

3.2. RS-480 and RS-481 connections

RS-480

Handset cables

Handset cables

Wall surface

RS-481

RS-480 (top)

Note
When using the RS-481 Option handset, cut the jumper
wire next to the handset joint connector on the circuit board
as illustrated above.
If not cut, sound comes out from the RS-480's front
speaker and returns back to the handset’s microphone,
resulting in acoustic feedback.

Jumper wire

Handset joint
connector

4. WALL MOUNTING

Mount the RS-480/481 to an electrical box mounted in the wall.

[RS-480]

RS-480

120

46

50.5

200 or less

44.5

3

200 or less

83.5

11

5

[Dimensional diagram]

Unit: mm

YC-302
2-gang electrical box
(option)

Machine screw M4 x 25
(accessory)

Wall surface

Seal the panel edges.

RS-480's front panel

Notes
• When using the PA paging function,

keep the switch panel as far away
from the PA paging speaker as
possible to avoid acoustic feedback.

• When installing the RS-480 at

outdoor or locations where it gets wet
with water, tightly seal the panel
edges. Besides, provide a weep hole
at the underside of the mounting box
to permit water to drain off.

[RS-481]

116

71

46

48

200 or less

Unit: mm

83.5

11

5

220

RS-481

[Dimensional diagram]

YC-302
2-gang electrical box
(option)

Machine screw M4 x 25
(accessory)

Wall surface

Accessory screws

The RS-480/481 come with 2 types of screws to match the box screw threads:
M4 x 25 and UNC No. 6-32 x 18.
For the electrical box provided with unified threads, use the UNC No. 6-32 x 18.

Advertising
This manual is related to the following products: