Unit Preparations

4. Remove the bracket from the wall and drill

1/4” diameter hole by 3” deep positioned in
the center of each mark. For applications
using metal studs and 3/16” toggle bolts,
drill the required clearance hole.

5. Reposition the bracket onto the wall and

align mounting slots/holes. Insert the two
lag screws provided (or toggle bolts for
metal studs) through the mounting
slots/holes and loosely tighten.

6. Level bracket and tighten screws (bolts for

metal studs) securely making sure not to
over-tighten to avoid damaging drywall or
plaster.

Wall Bracket Installation - Solid Walls

1. Locate the general area of the boiler place-

ment.

2. Place the wall-mounting bracket on the

wall ensuring the upper edge of the bracket
is away from the wall.

3. Level the bracket and use a pencil to mark

the location of the mounting slots on the
wall.

4. Remove the bracket from the wall and drill

a 5/8” diameter hole by 1-3/8” deep posi-
tioned in the center of each mark.

5. Install the anchors (provided) flush or

slightly recessed in the drilled holes with
threaded side facing down.

6. Reposition the bracket on the wall and

align mounting slots/holes. Insert the two
bolts (provided) through the mounting
slots/holes and loosely tighten.

7. Level bracket and tighten bolts securely.

Boiler Mounting

1. Obtain assistance in lifting the boiler onto

the wall bracket.

2. Install the boiler making sure the boiler

mounting lip located along the upper edge
of the rear jacket panel engages the wall-
mounting bracket. Ensure the boiler is
seated properly and is secure.