One-piece door with track, 5closed position, Closed position – Chamberlain 8200 1/2 HP User Manual

Page 5

Advertising
background image

Safety Reversing Sensor

FINISHED CEILING

Support bracket

& fastening

hardware is required.

See page 17.

Safety

Reversing

Sensor

Header

Wall

Access Door

Gap between floor and bottom

of door must not exceed 1/4".

5

Closed Position

Belt

Pulley Bracket

Header

Bracket

Trolley

Straight

Door

Arm

Manual

Release

Rope & Handle

Door

Bracket

Curved

Door

Arm

Header

Wall

Belt

T-rail

Garage

Door

Before you begin, survey your garage area to see whether any of the conditions below apply to your installation.
You may find it helpful to refer back to this page as you proceed with the installation of your opener.

Based on your particular requirements, there are
several installation steps which might call for
materials and/or hardware not included in the carton.

• Step 1, page 13 - Look at the wall or ceiling above

the garage door. The header bracket

must be

securely fastened to structural supports.

• Step 5, page 17 - Do you have a finished ceiling in

your garage? If so, a support bracket and additional
fastening hardware (not supplied) may be required.

• Safety reversing sensor, page 21 - Depending on

garage construction, extension brackets (see
Accessories) or wood blocks may be needed to
fasten sensors to mounting locations.

• Step 10, page 22 - Floor mounting of the safety

reversing sensor will require hardware that is not
provided.

• Step 11, page 25 - Generally, a one-piece door

does not require reinforcement. If your door is
lightweight, you can refer to the information
relating to sectional doors on page 24.

• Step 11, page 25 - Depending on your door's

construction, you might need additional mounting
hardware for the door bracket.

• Do you have an access door in addition to the

garage door? If not, Model 7702CB Outside Quick
Release is required. See page 38.

The gap between the bottom of the garage door

and the floor cannot exceed 1/4". Otherwise, the
safety reverse system may not work properly.
See page 30. The floor or the door should be repaired.

ONE-PIECE Door Installation

One-Piece Door without Track

Access

Door

Floor must be level

across width of door

Safety

Reversing Sensor

Safety

Reversing

Sensor

One-Piece Door With Track

Closed Position

Header

Bracket

Belt

Pulley Bracket

Door

Bracket

Straight

Door

Arm

Curved

Door Arm

Trolley

Manual Release

Rope & Handle

T-rail

Garage

Door

Belt

Header

Wall

Advertising