Hold operation:

For weighing large parcels or letters,

1. Switch the scale ON.
2. Select the desired class of mail.
3. Apply letter/parcel to scale. The scale displays the appropriate price.
4. Press

the

HOLD (8) key. The display briefly shows “HoLd”.

5. Remove the letter/parcel and the display will continue to show price.
6. To remove the Hold function, press the HOLD (8) key again; scale display briefly shows

“-HoLd”.

NOTE: For zoned rates, it will be necessary to key-in the ZIP code prior to pushing the Hold
key.

Auto Shut-off:

When shipped from the factory, the scale is configured to automatically switch off after 2 min-
utes if not in use. You may disable this feature by performing the following steps:
1.

Switch the scale OFF.

2.

Press and hold the CAN (1) key while turning the scale back ON.

3.

When the scale displays dashes (“- - - - -“), you may release the CAN (1) key. The scale
shows “A-oFF” briefly and then the current status of this feature (“on” or “oFF”).

4. Use

the

GP (4) key to toggle the status between “on” and “oFF”.

5. Press

the

ON (9) key to save the current setting and return to normal operating mode.


Calibration

Your TP-10 postal scale is ready to use right out of the box. There is no need to calibrate

the scale unless you feel that the scale has become inaccurate. It is a good idea to check
the calibration of your scale from time to time with a precision test weight.

1. Remove all items from the platter and turn the scale OFF. Press and hold the MEX (2) key

while turning the scale back ON.

2. When the scale displays dashes (“- - - - -“), you may release the MEX (2) key. The scale

shows “CAL” briefly then “ZERO”.

3. Press

the

Zero/CE key. The scale then shows “SAvE” briefly and then “5 0.0”.

4. Place a 5 pound test weight on the platter. The scale displays “Err” and then “5 0.0”.
5. Press

the

ON (9) key to save the 5 pound calibration value. Once the 5 pound calibration

value has been saved, the scale shows “SAvE” and then “End”. The scale then reverts to
normal operation mode.

Changing the origination ZIP code setting:

If you change locations or just simply notice at start-up that your origination ZIP code is not set
correctly, you may re-program it by performing the following steps:
1. Switch the scale OFF.
2. Press and hold the GP (5) key while turning the scale back ON.
3. When the scale displays dashes (“- - - - -“), you may release the GP (5) key. The scale

shows “CLR” briefly then “oZIP”.

4. At the “ENT ZIP” prompt, enter the first three digits of your ZIP Code. For example, if your

ZIP code is 60089, then you would enter 600. The scale displays the ZIP Code entered and
then resumes normal operation.