TRUE Systems P2 ANALOG User Manual

Page 16

Advertising
background image

P2

analog

OPERATION MANUAL

16

TROUBLESHOOTING

T

Symptom

No signal output. Main power switch
is on, but no LED’

s are illuminated.

Solution

 Check AC power source and cord.

 Check fuses (pull fuse drawer under power

cord inlet)

No signal output. Main power switch
is on and some LED’

s are

illuminated.

 Check status of phantom power.

 Check continuity of mic and electric

instrument cables.

 Check continuity of output cables.

Output signal is distorted. Outputs
are

connected

for

balanced

operation.

 Make sure gain is adjusted so that the OL

indicator does not activate during the audio
program.

 Make sure the high output capability of this

unit is not overloading the device or
monitoring system to which it is connected -
set GAIN selector to match capability of
device or monitoring system, then adjust gain
control according to indications on the Level
Indicator LED’

s.

 Check continuity of output cable.

 Make sure outputs are not connected to a

load impedance of less than 600 ohms.

Output signal is distorted. Outputs
are connected for unbalanced
operation
.

 Make sure the minus (-) output signal pins are

connected to the shield and not left
unconnected. See “Output Cable Connection”
section.

 Check troubleshooting tips for balanced

operation (above).

Hum can be heard in the audio
program.

 Disconnect grounding LINK.

 Check continuity of output cables (particularly

shields).

 Disconnect shields on one end of output

cables. Connect grounding LINK.

Channel 1 signal can be heard in
Channel 2 output - and vice versa.

 Check status of M-S selector. It should be

OFF for individual channel mode and ON for
Mid-Side mode.

Channel 2 seems to have no output
when used with Channel 1 as a
stereo pair

 Check status of M-S selector. It should be

OFF for individual channel mode and ON for
Mid-Side mode.