Mounting options wiring options ducting options, Use and care, Page 3 – Twin City Inline / Cabinet Ventilators - TL Series User Manual

Page 7: Right angle blower discharge), Blower discharge positions wiring plate position, Ducting

Advertising
background image

Page 3

MODELS

T400L • T500L • T700L

21½"

9

1

/

2

" to

10

1

/

2

"

21½"

10

3

/

4

" to

11

3

/

4

"

MOUNTING OPTIONS

WIRING OPTIONS

DUCTING OPTIONS

21½"

1

1

/

8

"

MAX.

(Outlet parallel to joists.)

(New construction)

12¼"

¼-20 hex nuts secure mounting brackets to housing. Loosen and

re-tighten or remove and replace nuts as necessary for desired

mounting bracket position.

(Outlet perpendicular to joists.)

(New construction)

(Outlet parallel to joists.)

(New or existing construction)

1

1

/

2

"

to

2

1

/

2

"

21½"

(Outlet parallel to joists.)

(New construction)

(Outlet parallel to joists.)

(New or existing construction)

BLOWER DISCHARGE POSITIONS

WIRING PLATE

POSITION

HORIZONTAL POWER

CABLE CONNECTION

DUCT CONNECTOR

BLOWER

Change

blower

& duct

connector

positions for

right angle

discharge.

DUCTING

(Right angle blower discharge)

ROOF CAP

10”

ROUND

DUCT

WARNING: To reduce the risk of electric shock,

disconnect from power supply before servicing.

To clean blower assembly: Remove access panel, unplug blower

from housing, remove blower mounting nuts, and carefully remove

blower from housing. Use appropriate vacuum attachment or a soft

cloth and mild soap or detergent to clean blower discharge area

and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make

sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may

be controlled using an on/off switch or a solid-state, variable speed

control. Follow wiring instructions packed with control, and adhere

to all local and state codes, and the National Electrical Code.

4½” X 18½”

TO 10” ROUND

TRANSITION

21½"

1½"

to

2½"

(Outlet parallel to joists.)

(Existing construction)

DUCT CONNECTOR

BLOWER

VERICAL

POWER

CABLE

CONNECTION

Mounting brackets in

factory-shipped position.

Mounting brackets flipped

over and mounted to outlet

sides of housing.

Mounting brackets mounted

to outlet sides of housing.

Mounting brackets flipped

over to give approx. 1”

more clearance.

Mounting brackets mounted

to top of sides of housing.

Mounting brackets flipped

over and mounted to top of

sides of housing.

Wiring plate mounts to side or top of housing.

Typical ductwork connection to a ventilator

converted to right angle discharge.

Blower and duct connector

in straight-through

discharge position

(factory shipped).

Blower and duct connector

in right-angle

discharge position.