NATURAL GAS CONNECTION

The regulator supplied is set for 4” water column and is for use with Natural gas only.

The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).

The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psi.

A typical natural gas installation is shown above. Make sure the factory supplied regulator is used and
installed with the arrow mark on the regulator pointing in the same direction as the gas flow going from the
supply line to the Dine & Breakfast Club. The regulator is preinstalled onto the end of the manifold. Use only
the regulator provided as original equipment with your Dine & Breakfast Club. Use only pipe sealants that are
approved for use with natural and LP gases. An installer supplied gas shutoff valve must be installed in an
accessible place

.