Gas heater (tegh) conversion procedure – Twin Eagles Gas Heater NG to LP Conversion User Manual

Page 2

Advertising
background image

Gas Heater (TEGH)

Conversion Procedure

Doc. No.

SB-02A

Rev. (Rev. Date)

Apr. 8, 2011

Written by:

Eng. Approval:

Page 2 of 2

Mfg. Approval:

4) Remove the rate screw orifice with a flat screwdriver; you

may need to use pliers to pull the rate screw of the cavity. Replace

the rate screw orifice accordingly (Blank stud for NG or 1.7mm.

# 51 for LP).

5) Remove the black rubber cover from the valve. Push and turn

the stem converter 90

o

until the indicator slot is pointing towards

the gas type being converted to. Place the black rubber cover

back on.

6) Open the gas supply to the unit and conduct an applicable

leak test. Consider the unit operational only if no gas leak is found.

7) With a permanent marker, write the following information on the conversion label, such as: Model number

indicate on the serial plate, gas converted to, date of the gas conversion, service agency name, address and

contact phone number. Without covering the holes on the access door paste the label on the access door as

shown on picture 1.

8) Gas conversion is complete

NG

NG

LP

LP

5)

4)

Orifice, Rate Screw

NOTE: On LP conversion, the rate screw orifice may need
to be turned back out by 1 to 2 turns for the burner to have
a stable flame on the low setting.

Advertising