Operating instructions – Chicago Electric 43150 User Manual

Page 6

Advertising
background image

Page 6

for technical questions, please call 1-800-444-3353.

SKU 43150

operating inStructionS

read the entire important

SafetY information

section at the beginning of this

manual including all text under

subheadings therein before set

up or use of this product.

tool Set up

to preVent

SeriouS injurY

from acciDental

operation:

turn the power Switch of the

tool off and remove the

batteries before adjusting tool

or installing accessories.

figure 2

Lock Nut (31)

Tapered Bushing (30)

Threaded Lock Ring (29)

Upper Leg (25)

note: When adjusting the length of the

Metal Detector, be careful to keep

the plastic Tapered Bushing (30) in

place with the smaller end toward the

smaller end of the Lock Nut (31).
To attach the two legs, slide the

1.

Threaded Lock Ring (29) over the

end of the Upper Leg (25), making

sure that the tabs inside the Lock

Ring lock into the cut-outs at the end

of the leg. Insert the tapered end of

the Tapered Bushing (30) into the

Lock Nut (31) and lightly thread the

Nut over the Lock Ring (29). Slide the

Lower Leg (26) into the Lock Nut. To

take the slack off the cord, rotate the

Lower Leg, enabling the cord to wind

around the two Legs. Rotate the Nut

counterclockwise to lock the Legs.
To adjust the length of the Legs, turn

2.

the Lock Nut in a clockwise direction,

slide the Lower Leg to the desired

extension length and turn the Nut

counterclockwise to secure the Legs

together.
To adjust the angle of the Search

3.

Coil, loosen the Adjusting Knobs (28,

32) and tilt it. Position the Search

Coil so that it is parallel to the ground

when holding the unit by the Handle

(3, 4).
If needed, re-adjust the length of the

4.

Metal Detector after adjusting the

position of the Search Coil.

Batteries

Make sure the On/Off/Volume control

1.

is set to OFF. Slide the Battery Cover

(20) off of the back of the Control

Box and insert six AA batteries (sold

separately), aligning polarities as

indicated. Replace the Battery Cover.

note: Use only fresh batteries of the

required size and type. Do not mix

old and new batteries, different types

(standard, alkaline, or rechargeable),

or rechargeable batteries of different

capacities.
Always remove old or weak batteries.

Batteries can leak chemicals that can

destroy electric parts.
If you do not plan to use the detector

for a week or more, remove the

batteries.
Dispose of spent batteries according

to your local, state and federal

regulations.

Advertising