TROUBLESHOOTING

Both LEDs are off :
Check power source is available and functional.

Amber LED is off :
Check Ethernet cable is securely connected.

Internet browser cannot connect to TIMENET :
Verify IP address of PC is on the same domain as TIMENET.

TIMENET does not get a GPS lock :
Check the status page of TIMENET.

• If the SNR column shows several entries, some with high

values then wait a few minutes and check again.

• If the SNR column shows very few entries /low values then

check that the antenna is mounted in a suitable position with

a clear view of the sky.

Clients will not synchronise to TIMENET :
If TIMENET has just been powered up, then wait 30minutes
and try again.

FURTHER INFORMATION
For the latest product information and application notes please
visit our website: www.veracityglobal.com

Product Code VTN - TN

SET UP (3)

To change the default password:

1. Click on the Administration tab.

2. Type in the new password and click on Save.

Please note that any future use of the Configuration page will
require the new password to be used.

To reset TIMENET to its default settings, either :

1. Click on the Administration tab and select Restore Factory

Settings or :

2. Use a paper clip to press the reset button (see connections

diagram) and TIMENET will re-boot with the default settings.

SET UP (1)

1. Connect a PC to the same network as TIMENET.

The default IP address of TIMENET is 192.168.42.7

2. Configure the network settings of the PC to the same domain

(e.g. 192.168.42.100).

3. Start an internet browser and navigate to 192.168.42.7

This will connect the PC to TIMENET.

4. Enter the password. This will display the TIMENET

Configuration Status page. The default password is admin

SET UP (2)

To change the IP address setting for your application:

1. Click the Network Settings tab and enter the IP Address,

Subnet Mask and Gateway.

2. Click on Save to write the settings to TIMENET.

This will automatically cause TIMENET to re-boot with

the new IP settings. This will take approximately 60 seconds.

3. Be sure to change the PC to the new IP domain before
re-checking

TIMENET operation.