ELECTRONIC THERMOSTAT: C1110

FOR ANALOG ZONE VALVES

• Modulating 0 to 10 Vdc analog output

• For N.O. or N.C. valves

• For heating or cooling applications

DESCRIPTION

The C1110 series thermostats are microcomputer-based,
proportional and integral (PI) devices with one analog 0 to
10 Vdc output. The thermostat are designed to be used with
analog valve actuators. The action of the output ( direct or
reverse acting ) can be adjusted with an internal dip switch.

HOW TO ORDER

C1110

-


01 = °C & °F scale with blind cover
Internal setpoint adjustment

02 = 10 to 30 °C scale

03 = 50 to 90 °F scale

DIMENSIONS

SPECIFICATIONS

Operating Conditions:

0 °C to 50 °C ( 32 °F to 122 °F )
0% to 95% R.H. non-condensing

Sensor:

Local 47 K NTC thermistor

Resolution:

± 0.1 °C ( ± 0.2 °F )

Control accuracy:

± 0.2 ° C ( ± 0.4 °F ) ( calibrated )

Ranges:

10 °C to 32 °C ( 50 °F to 90 °F )

Proportional band for room

temperature control:

1.8°C ( 3.2°F )

Analog output:

0 to 10 Vdc into 2K

Ω resistance min.

Power:

24 Vac -15%, +10% 50/60 Hz; 2 VA

THERMOSTAT INSTALLATION

Important.
Electronic controllers require special care for wiring
and startup. To avoid problems, carefully follow the
procedures below.

Be sure to have all the literature on hand for all components
installed: controller, actuators, relay, etc...

Look at the wiring diagrams, and study them carefully. Be
sure that you understand how the system is supposed to
work.

Make the wiring according to the wiring diagrams. Respect
polarity for power terminals # 3 & # 4 between multiple
controllers if the same transformer is used.

Remove security screw on left side of thermostat cover.

Open up by pulling on the bottom side of thermostat.

A) Location:

1- Shouldn’t be installed on outside wall.
2- Must be installed away from any heat source.
3- Shouldn’t be affected by direct sun radiation.
4- Nothing must restrain vertical air circulation to the

thermostat.

B) Installation:

1- Pull out cables 6” out of the wall.
2- Wall surface must be flat and clean.
3- Separate the thermostat and the base by pulling

the cover by the bottom (same as the security
screw.)

4- Insert cable in the central hole of the base.
5- Align the base and mark the location of the two

mounting holes on the wall. Install proper side of
base up.

6- Install shields in the wall.
7- Insert screws in mounting holes on each side of the

base. DO NOT OVERTIGHTEN!

8- Strip each wire 1/4 inch.
9- Insert each wire according to wiring diagram.
10- Reinstall the cover ( top side first ) and gently push

back extra wire length in the hole in the wall.

11- Install security screw.

32 mm

( 71 mm )

2.8"

1.275"

( 83 mm )

3.275"

SECURITY SCREW

OR FROM BACK

FROM TOP

WIRING

BASE

( 114 mm )

4.5"