Circulator dimensions – Vogelzang VG820E (new as of 2013) User Manual

Page 2

Advertising
background image

2

19

TOOLS AND MATERIAL NEEDED

NOTES

TOOLS

Pencil
6 Foot Folding rule or tape
Tin Snips
Drill, hand or electric
Drill bit, 1/8" dia.
(for sheet metal screws)
Gloves
Screwdriver (blade-type)
5/16" Nut Driver or
5/16" Socket w/Ratchet

ELECTRICAL

120 Volts
60 Hertz
0.55 Amps

MATERIALS

Chimney Connection- 6" Dia. Black
Steel (24 Ga. minimum): Straight or
corrugated elbow (as required)*
1/2" Sheet Metal Screws
6" Inside Diameter Underwriters
Laboratories (UL) listed Residential
Type and Building Heating Appliance
Chimney, Type "HT", or 6" existing
Masonry Chimney with fl ue liner.
Floor Protector Material: 3' x 4'-6" as
specifi ed on page 4.
Furnace Cement (Manufacturer
recommends: Rutland Code 78 or
Equivalent)
* Avoid adjustable elbows, they leak!

CIRCULATOR DIMENSIONS

Fig. 1

32 1/4

12 1/2

33 1/2

4 1/8

4 1/4

19 1/4

CENTER LINE OF 6"
CHIMNEY CONNECTOR

24

TOP OF FLOOR PROTECTOR

CENTER LINE
OF 6"
CHIMNEY
CONNECTOR

RULES FOR SAFE INSTALLATION AND OPERATION

Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death.
SAFETY NOTICE: If this heater is not properly installed, a house fi re may result. For your safety, follow the
installation directions. Contact local building or fi re offi

cials about restrictions and installation inspection

requirements in your area.

1.

Check local codes. Th

e installation must

comply with their rulings. Do not install this
heater in a mobile home or trailer.

2.

Always connect this heater to a chimney or vent
to the outside. Never vent to another room or
inside a building.

3.

Do not connect a WOOD burning heater
to an aluminum Type B gas vent. Th

is is not

safe and is prohibited by all codes. Th

is heater

requires connection to approved chimneys:
Either a factory built 6" UL 103HT or a lined and ap-
proved and recently inspected and cleaned masonry
chimney with a 6" fl ue, preferably round. A larger
masonry fl ue may be used, so long as the fl ue-section
diameter is not greater than 50 sq. in. Th

e chimney

portion (whether factory-built, or masonry) must
be tall enough to provide suffi

cient draft and safe

exit of smoke and combustion products.

Advertising